MS48IP Programming Guide
53
Extension CID Mode:
Thanks to this program each extension can be programmed individually to receive
ETSI or Bellcore standard Caller ID information. The default is the ETSI standard.
Furthermore, through this program, the “Ext.” field in the internal call Caller ID
indication can be enabled or disabled. With this field disabled, if the name of the
calling subscriber is defined in the system, it is sent to the called subscriber.
Otherwise the phone ID is sent. Enabling this field lets the extension receive “Ext”
when the calling subscriber name is not defined.
8 7 7 6 5 0 1 A [ 9 ] F B
Parameters
A
:
The extension access code
F
:
0
ETSI
:
1
Bellcore
B
:
0
“Extension” name is sent
:
1
“Extension” name is not sent
Default Value
F = 0 and B = 0 for all extensions
Notes
1. After entering 8776 5, if an extension whose name has been defined through
Net-Console calls, the name information of the extension will be displayed on
the otherside. If there is no name definition made through Net-Console, only
the number of the extension will be displayed.
2. For single line LCD telephones, it will be supplied to be displayed the telephone
number with entering “1” for parameter B.
3. This program will be supported with the Net-Console release AAS.