− 92 −
(5) Observing the operation measurement information
①
Display the operation measurement screen
Press OPERATION MEASUREMENT SCREEN DISPLAY button
A
in the information screen. The operation measurement
screen (screen A) is displayed.
Information on the following 5 items is displayed in the operation
measurement screen.
Ⓐ
: This item automatically displays the operation rate from the
time of starting the measurement.
Ⓑ
: This item automatically displays the mean machine speed
from the time of starting the measurement.
Ⓒ
: This item automatically displays the mean pitch time from the
time of starting the measurement.
Ⓓ
: This item automatically displays the mean machine time from
the time of starting the measurement.
Ⓔ
: This item displays the number of times of thread trimming per
process.
Input the number of times referring to item
②
below.
②
Input the number of times of thread trimming
Next, input the number of times of thread trimming per process.
Press NUMBER OF TIMES OF THREAD TRIMMING button
Ⓔ
and the number of times of thread trimming input
screen is displayed.
Input the value you desire with ten keys or UP/DOWN buttons.
After the input, press ENTER button
B
.
* When the input value is “0”, count of the number of times of
thread trimming is not performed. Use this function by con-
necting the external switch.
B
Operation measurement
screen (Screen A)
Ⓐ
Ⓒ
Ⓑ
Ⓓ
Ⓔ
A