− 55 −
※
. . . Item that is not displayed due to other setting state
No.
Item
Setting range
/
Edit unit
Initial value
Setting of (left) corner knife motion position at the start of sewing
Motion (longitudinal) position of left corner knife at the start of sewing is set.
–9.9 to
9.9mm
/
0.1mm
0.0mm
Setting of (right) corner knife motion position at the start of sewing
Motion (longitudinal) position of right corner knife at the start of sewing is
set.
–9.9 to
9.9mm
/
0.1mm
0.0mm
Setting of (left) corner knife motion position at the end of sewing
Motion (longitudinal) position of left corner knife at the end of sewing is set.
–9.9 to
9.9mm
/
0.1mm
0.0mm
Setting of (right) corner knife motion position at the end of sewing
Motion (longitudinal) position of right corner knife at the end of sewing is set.
–9.9 to
9.9mm
/
0.1mm
0.0mm
Marking light setting
Marking light irradiation position in each case of sewing start irradiation/
sewing end irradiation/center irradiation is set. When set value 0.0n mm,
the sewing position is the same as the marking light irradiation position.
Use this function when irradiating the marking light to the position that is
different from the sewing position.
–100.0 to
100.0
* Sewing
start irradia
-
tion :
–80.0 to
100.0
/
0.1mm
0.0mm
Sewing start irradiation
Sewing end irradiation
Center irradiation