− 10 −
B
A
9. REMOVING THE HEAD FIXING PLATE
Remove fixing screws
❷
of head fixing plate
❶
.
Be sure to fix the machine and the frame
when performing re-transportation.
10. INSTALLING THE SUB-TABLE
Install the sub-table with four screws
❶
as shown in
the figure.
11. INSTALLING OPERATION PANEL IP-420
As shown in the figure above, open the lid on the right-hand section
B
of IP-420 and connect the connector
which is fixed with tape to the right-hand top surface
A
of the table.
To prevent malfunction due to static electricity, install operation panel IP-420 on the panel base
to use and do not change the position of the panel base.
At this time, fix the sub-table so as to be
flush with the main table.
Tape
Connector
❶
❶
❶
❷