− 125 −
②
When FOOT PEDAL ADJUSTMENT button
B
is pressed,
the foot pedal adjustment screen is displayed and the number of
steps in terms of the depressing depth of the foot pedal is set.
③
Pedal sensor voltage value in the present pedal depressing state
is displayed in the range of 0 to 99 in the volume bar indication
C
.
First, press PEDAL DEPRESSED TO REVERSE STEP INPUT
button
D
with the foot pedal depressed to the reverse step. Volt-
age value of this time is inputted to
E
. Next, press FREE INPUT
button
F
with the foot pedal free. Voltage value of this time is
inputted to
G
. Using the same procedure, perform setting of first
to seventh steps of the foot pedal, and input the voltage value of
the respective pedal positions to buttons
E
,
G
and
H
.
Set the voltage value so as to increase as the number of steps of the foot pedal increases.
In addition, when directly pressing button
E
,
G
or
H
, the ten key input screen is displayed, and
it is possible to directly input numerals.
B
H
C
G
E
F
D