− 134 −
Error code
Description of error
How to recover
E486
Flap sewing data cannot be sewn.
Possible to re-
start after reset.
E487
Both long presser and endless zipper are simultaneously
selected.
Possible to re-
start after reset.
E488
- - -
The gauge size exceeds the input range.
Possible to re-
start after reset.
E489
Combination data other than right/left flap sewing is set at
the time of flap priority setting of alternate sewing mode.
Possible to re-
start after reset.
E490
It is not possible to feed up to corner knife position.
When flap is put on this side in case of the long type
Possible to re-
start after reset.
E491
Corner knife length is too short.
When knife cannot be entered since the interval of corner knife is
short.
Possible to re-
start after reset.
E492
L size length is too short.
When sewing cannot be performed since the inputted L size
length is too short
Possible to re-
start after reset.
E493
L size length is too long.
When sewing cannot be performed since the inputted L size
length is too long.
Possible to re-
start after reset.
E494
Center knife length error
When center knife length is smaller than knife size of 6.7 mm
Possible to re-
start after reset.
E495
Length at sewing start/sewing end over
When sewing length is shorter than the total of length of each
condensation (back tack) at sewing start and sewing end
Possible to re-
start after reset.