− 69 −
No.
Item
Setting range
/
Edit unit
Initial value
Changeover of compensation of flap concealed stitching position
using deflection detection
When the automatic deflection detection of left flap is not set, compen-
sation of flap concealed stitching is automatically performed using the
second flap sensor.
* When the automatic deflection detection is set, compensation of flap
concealed stitching is automatically performed regardless of with/
without this setting.
- - -
Used
Not used
Changeover of right/wrong side of material in the corner knife
setting screen
Material displayed in the corner knife setting screen is selected to right
side display or wrong side display.
- - -
Right side display
Wrong side display
Stacker timer 5
Sets the waiting time of the stacker from the start of material grasping
operation to the release of the material
This setting is available when
"Grasping stacker (optional)" is used.
0.00 - 9.99/
0.01 sec
1.00 sec
Stacker timer 6
Sets the duration of operating the oscillating arm
This setting is available when
"Grasping stacker (optional)" is used.
0.00 - 9.99/
0.01 sec
1.50 sec
Number of stitches of grease-up
Number of stitches of sewing machine motion after replenishing grease
is indicated.
* When pressing CLEAR button, number of stitches is cleared to “0”.
Be sure to clear after replenishing grease.
- - -
- - -
Language selection
Language to be indicated in the panel is selected.
- - -
No selection
Japanese
English
Chinese (traditional)
Chinese (simplified)
Spanish
Italian
French
German
Portuguese
Portuguese
Vietnamese
Korean
Indonesian
Russian
※
. . . Item that is not displayed due to other setting state