40
3.OPERATIONS
TEMP LOWER ALARM
FUNCTION "ON"
TEMPERATURE LOWER ALARM
MARK RETURN TO ALARM MENU
GRAPH CLOSE MENU
ON
▼
▲▲
▲ FUNCTION
UPPER LIMIT
OFF
17.0。
C
Setting the TEMP UPPER alarm
The TEMP UPPER alarm can be
activated when water temperature
increases above the specified value.
Use the TEMP UPPER alarm menu to
specify the temperature upper limit.
The change in water temperature
that can be specifed range from
-10 degC to +50 degC.
The TEMP UPPER alarm setting procedure is shown below.
1
Display the main menu by pressing the
and
keys together.
2
Move control to "ALARM" by pressing the
or
key, and
then display the ALARM SETTING submenu by pressing the
key.
3
Move control to "TEMP UPPER" by pressing the
or
key,
and then display the TEMP UPPER ALARM submenu by
pressing the
key.
4
Move control to "FUNCTION" by pressing the
or
key, and
then select "ON" by pressing the
or
key.
5
Move control to "UPPER LIMIT" by pressing the
or
key,
and then specify the desired alarm activation water temperature
value by pressing the
or
key.
Example: 20.0 degC. (for activating the alarm when water
temperature increases above 20.0 degC.)
6
Press the
MARK
key to return to the ALARM MENU.
7
Press the
GRAPH
key to return to the fishfinding display.
Setting the TEMP LOWER alarm
The TEMP LOWER alarm can be
activated when water temperature
decreases below the specified value.
Use the TEMP LOWER alarm menu to
specify the temperature lower limit.
The change in water temperature
that can be specifed range from
-10 degC to +50 degC.
The TEMP LOWER alarm setting procedure is shown below.
1
Display the main menu by pressing the
and
keys together.
2
Move control to "ALARM" by pressing the
or
key, and
then display the ALARM SETTING submenu by pressing the
key.
3
Move control to "TEMP LOWER" by pressing the
or
key,
and then display the TEMP LOWER ALARM submenu by
pressing the
key.
4
Move control to "FUNCTION" by pressing the
or
key, and
then select "ON" by pressing the
or
key.
5
Move control to "LOWER LIMIT" by pressing the
or
key,
and then specify the desired alarm activation water temperature
value by pressing the
or
key.
Example: 17.0 degC. (for activating the alarm when water
temperature decreases below 17.0 degC.)
6
Press the
MARK
key to return to the ALARM MENU.
7
Press the
GRAPH
key to return to the fishfinding display.
TEMP UPPER ALARM
FUNCTION "ON"
TEMPERATURE LOWER ALARM
MARK RETURN TO ALARM MENU
GRAPH CLOSE MENU
ON
▼
▲▲
▲ FUNCTION
UPPER LIMIT
OFF
20.0。
C
Main menu
ALARM
MAIN MENU
DEPTH/TEMP
STD. 1 2 3
STD. 1 2 3
10
5
OFF AUTO RANGE
AUTO SHIFT
PRESET
▲▲
GOTO SUB MENU
GRAPH
▲
▲
▲
▲
▲
▲
▲
▲
COLOR MODE
BACK COLOR
USER COLOR
D I S P L A Y
G R A P H
A L A R M
STD. RANGE
ZOOM RANGE
BOTTOM RANGE
AUTO MODE
CLOSE MENU
ALARM
TEMP UPPER
▲
▲
▲
▲
▲
▲
GOTO SUB MENU
▲
ALARM MENU
MARK RETURN TO MAIN MENU
GRAPH CLOSE MENU
▼
▲
F I S H
SHALLOW
D E P T H
TEMP UPPER
TEMP LOWER
TEMP RATE
Changes
in water temperature
Alarm
Water temp. upper limit value
Water temp. lower limit value
Changes
in water temperature
Alarm
ALARM
TEMP LOWER
▲
▲
▲
▲
▲
▲
GOTO SUB MENU
▲
ALARM MENU
MARK RETURN TO MAIN MENU
GRAPH CLOSE MENU
▼
▲
F I S H
SHALLOW
D E P T H
TEMP UPPER
TEMP LOWER
TEMP RATE