3.OPERATIONS
39
Setting the SHALLOW alarm
The SHALLOW alarm can be activated
w h e n t h e d e t e c t e d w a t e r d e p t h
decreases below the specified value.
Use the SHALLOW alarm menu to
specify the water depth.
The SHALLOW alarm setting procedure
is shown below.
1
Display the main menu by pressing the
and
keys together.
2
Move control to "ALARM" by pressing the
or
key, and then
display the ALARM SETTING submenu by pressing the
key.
3
Move control to "SHALLOW" by pressing the
or
key, and
then display the SHALLOW ALARM submenu by pressing the
key.
4
Move control to "FUNCTION" by pressing the
or
key, and
then select "ON" by pressing the
or
key.
5
Move control to "DEPTH" by pressing the
or
key, and then
specify the desired alarm activation water depth value by pressing
the
or
key.
Example: 10 m (for activating the alarm when the detected water
depth decreases below 10 m)
6
Press the
MARK
key to return to the ALARM MENU.
7
Press the
GRAPH
key to return to the fishfinding display.
Main menu
ALARM
MAIN MENU
DEPTH/TEMP
STD. 1 2 3
STD. 1 2 3
050
010
OFF AUTO RANGE
AUTO SHIFT
PRESET
▲▲
GOTO SUB MENU
GRAPH
▲
▲
▲
▲
▲
▲
▲
▲
COLOR MODE
BACK COLOR
USER COLOR
D I S P L A Y
G R A P H
A L A R M
STD. RANGE
ZOOM RANGE
BOTTOM RANGE
AUTO MODE
CLOSE MENU
ALARM
SHALLOW
▲
▲
▲
▲
▲
▲
GOTO SUB MENU
▲
ALARM MENU
MARK RETURN TO MAIN MENU
GRAPH CLOSE MENU
▼
▲
F I S H
SHALLOW
D E P T H
TEMP UPPER
TEMP LOWER
TEMP RATE
SHALLOW ALARM
FUNCTION "ON"
SHALLOW ALARM
MARK RETURN TO ALARM MENU
GRAPH CLOSE MENU
ON
▼
▲▲
▲ FUNCTION
D E P T H
OFF
10m
Setting the DEEP alarm
The DEEP alarm can be activated when
the detected water depth increases
above the specified value. Use the
DEEP alarm menu to specify the water
depth.
The DEEP alarm setting procedure is
shown below.
1
Display the main menu by pressing the
and
keys
together.
2
Move control to "ALARM" by pressing the
or
key, and
then display the ALARM SETTING submenu by pressing the
key.
3
Move control to "DEEP" by pressing the
or
key, and then
display the DEEP ALARM submenu by pressing the
key.
4
Move control to "FUNCTION" by pressing the
or
key, and
then select "ON" by pressing the
or
key.
5
Move control to "DEPTH" by pressing the
or
key, and
then specify the desired alarm activation water depth value by
pressing the
or
key.
Example: 200 m (for activating the alarm when the detected
water depth increases above 200 m)
6
Press the
MARK
key to return to the ALARM MENU.
7
Press the
GRAPH
key to return to the fishfinding display.
ALARM
DEEP
▲
▲
▲
▲
▲
▲
GOTO SUB MENU
▲
ALARM MENU
MARK RETURN TO MAIN MENU
GRAPH CLOSE MENU
▼
▲
F I S H
SHALLOW
D E P T H
TEMP UPPER
TEMP LOWER
TEMP RATE
DEEP ALARM
FUNCTION "ON"
DEPTH ALARM
MARK RETURN TO ALARM MENU
GRAPH CLOSE MENU
ON
▼
▲▲
▲ FUNCTION
D E P T H
OFF
200m
Deep alarm depth
Alarm
Bottom
Shallow alarm depth
Alarm
Bottom