Table 3-15. Diagnostic Trouble Codes (Delta Q Battery Charger)
DTC
Fault
Solution
E-0-0-1
High Battery Voltage Error
Battery Voltage is too high to start charge. Check the battery voltage and cable connections.
Check battery size and condition. This error will automatically clear once the condition has been
corrected.
E-0-0-2
Low Battery Voltage Error
Battery Voltage is too low to start charge. Check the battery voltage and cable connections.
Check battery size and condition. This error will automatically clear once the condition has been
corrected.
E-0-0-3
Charge Timeout
Charge Timeout caused by battery pack not reaching required voltage within safe time limit.
Possible causes: Charger output reduced due to high temperatures or low AC voltage. Poor bat-
tery health. Very deeply discharged battery. Poorly connected battery. Extra loads. Battery too
large for algorithm selected.
Possible solutions: Improve cooling air flow. Check for low AC voltage. Replace battery pack.
Check DC connections. This error will automatically clear once the charger is reset by cycling DC.
E-0-0-4
Battery Defective
Battery could not be trickle charged up to the minimum voltage. Check for shorted or damaged
cells. Check battery pack voltage matches charger voltage. Replace battery pack. Check DC con-
nections. This error will automatically clear once the charger is reset by cycling DC.
E-0-0-5
Algorithm Specific Alarm
Contact Support for details if this alarm occurs.
E-0-0-6
Battery Temperature Sensor Short
Circuit
Check temperature sensor wiring for short to ground then restart the charge.
E-0-0-7
Charge amp hour limit exceeded
Safety limit exceeded. Possible causes: Poor battery health. Very deeply discharged battery.
Poorly connected battery. High parasitic loads on battery while charging.
Possible solutions: Replace battery pack. Check DC connections. Disconnect parasitic loads. This
error will automatically clear once the charger is reset by cycling DC.
E-0-0-8
Battery temperature is out of range
Possible battery temperature sensor error. Check temperature sensor and connections. Reset
charger. This error will automatically clear once the condition has been corrected.
E-0-0-9
Battery Temperature Changing Too
Quickly
Check loose/corrosion on output cable or bad configuration if the battery temperature sensor is
used for charge control.
E-0-1-0
Charger Output Short Circuit
Charger DC terminals in contact with each other while charging. Check for short circuit in
charging and battery cables.
E-0-1-1
Charger Disabled By External Com-
mand
Charger has been disabled by an external controller over the CANbus network. This error is
logged in the data log and the charger sends out a CAN message. It is not displayed.
E-0-1-2
Charger Output Reverse Polarity
Battery is connected to the charger incorrectly. Check the battery connections. This error will
automatically clear once the condition has been corrected.
E-0-1-3
Charger Output Current Not Accepted
Battery voltage is detected but the charger is unable to output current. This is normally caused
by an electrical device connected between the charger and the battery which passes through
voltage but not current. Poor connections can also cause this. Ensure the charger is properly
connected to approved equipment. This error will automatically clear once the charger is reset
by cycling DC or AC.
E-0-1-4
Configuration Error - Charger Cannot
Support Number of Battery Cells
The charger will need to be reflashed to the correct settings.
E-0-1-5
Configuration Error - Algorithm Does
Not Support Target Voltage Scaling
The charger will need to be reflashed to the correct settings.
E-0-1-6
Charger Programming Failure - Gen-
eral
Retry by removing and re-inserting the USB drive. Ensure correct files are being used. Ensure the
USB Flash Drive is properly formatted (FAT recommended) and retry. Try a different USB drive. If
error persists, contact Support.
Summary of Contents for ERT2669
Page 2: ......
Page 4: ...INTRODUCTION A 2 31215923 REVISON LOG Original Issue A January 08 2021...
Page 12: ...viii 31215923 TABLE OF CONTENTS...
Page 40: ...SECTION 1 SPECIFICATIONS 1 22 31215923...
Page 58: ...SECTION 2 GENERAL 2 18 31215923...
Page 187: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 11...
Page 206: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 4 30 31215923...
Page 225: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 31215923 4 49...
Page 242: ...SECTION 4 BASIC HYDRAULIC INFORMATION SCHEMATICS 4 66 31215923...
Page 307: ...SECTION 5 JLG CONTROL SYSTEM 31215923 5 65...
Page 334: ...SECTION 6 LSS SETUP CALIBRATION SERVICE 6 12 31215923...
Page 362: ...SECTION 7 GENERAL ELECTRICAL INFORMATION SCHEMATICS 7 28 31215923...
Page 374: ...SECTION 7 GENERAL ELECTRICAL INFORMATION SCHEMATICS 7 40 31215923...
Page 375: ......