nano3G AP Installation Manual
Installation Overview and Requirements
N3G_INST_300 v14.0 for N3G_2.85 © ip.access Limited 2012
Page 17
POE+ Injector
The POE+ injector unit is supplied as standard with each nano3G E8 AP and E16 AP. The
POE+ injector has two Ethernet connections, one for connection to the main LAN, the other
for connection to the AP. The POE+ injector can be located anywhere on the cable run
between the network switch and the AP, including locally at the AP or remotely at the
network switch.
The POE+ injector is a pass-through connector for the LAN. Its function is to add POE+ to
provide power to the AP. Therefore, the maximum cable run from the network switch to the
AP is 100m, regardless of the placement of the POE+ injector.
The POE+ injector supplied by ip.access complies with LPS requirements in accordance
with IEC/EN 60950-1.
2.4.2
nano3G E8 AP and E16 AP Physical Requirements
A nano3G E8 AP or E16 AP is installed by attaching its mounting plate to a wall or partition
with screws, then sliding the rear surface of the AP onto the mounting plate (see section
6.3.6).
Pay attention to ensure that air can circulate freely around the unit. The unit must be
vertical.
It is recommended to install the AP with its front surface facing the area requiring cellular
coverage, unobstructed by walls or partitions that may cause significant RF attenuation.
2.4.3
nano3G E8 AP IP Bandwidth Requirements
At maximum capacity and with IPsec in use, a nano3G E8 AP will require:
• Downlink: 17Mbps
• Uplink: 1.8Mbps
Dimensions and
weight
Height
211mm
Width
274mm
Depth
58.6mm
Approximate Weight
1.75 kg
Environmental
Cooling
Vents on the back at top and bottom
Operating Temperature
0°C to +45°C
Operating Humidity
10 to 70% non-condensing