Goodrive200L
inverters Function parameters
62
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P06.17
Lower limit of
AO1 output
The above function codes define the relative
relationship between the output value and analog
output. When the output value exceeds the range
of set maximum or minimum output, it will count
according to the low-limit or upper-limit output.
When the analog output is current output, 1mA
equals to 0.5V.
In different cases, the corresponding analog
output of 100% of the output value is different.
Please refer to each application for detailed
information.
1 0 V (2 0 m A )
0 .0 %
1 0 0 .0 %
A
O
Setting range of P06.18 0.00V~10.00V
Setting range of P06.19 P06.17~100.0%
Setting range of P06.20 0.00V~10.00V
Setting range of P06.21 0.000s~10.000s
Setting range of P06.22 0.0%~P06.24
Setting range of P06.23 0.00V~10.00V
Setting range of P06.24 P06.22~100.0%
Setting range of P06.25 0.00V~10.00V
Setting range of P06.26 0.000s~10.000s
Setting range of P06.27 0.000s~10.000s
Setting range of P06.28 0.00~50.00kHz
Setting range of P06.29 P06.27~100.0%
Setting range of P06.30 0.00~50.00kHz
Setting range of P06.31 0.000s~10.000s
0.0%
○
P06.18
Correspondin
g AO1 output
to the lower
limit
0.00V
○
P06.19
Upper limit of
AO1 output
100.0%
○
P06.20
The
correspondin
g AO1 output
to the upper
limit
10.00V
○
P06.21
AO1 output
filter time
0.000s
○
P06.22
Lower limit of
AO2 output
0.0%
○
P06.23
Correspondin
g AO2 output
to the lower
limit
0.00V
○
P06.24
Upper limit of
AO2 output
100.0%
○
P06.25
Correspondin
g AO2 output
to the upper
limit
10.00V
○
P06.26
AO2 output
filter time
0.000s
○
P06.27
Lower limit of
HDO output
0.00%
○
P06.28
Correspondin
g HDO
output to the
lower limit
0.00kHz
○
P06.29
Upper limit of
HDO output
100.0%
○
P06.30
Correspondin
g HDO
output to the
50.00
kHz
○