Goodrive200L
inverters Basic operation instruction
111
Function
code
Name
Description
Setting
Range
Modify
Factory
setting
P01.06
The start time of
S-curve
acceleration
setting
0.0~50.0s
0.0~50.0
○
1.5s
P01.07
The arrival time of
S-curve
acceleration
setting
0.0~50.0s
0.0~50.0
○
1.5s
P08.00
The start time of
S-curve
deceleration
setting
0.0~50.0s
0.0~50.0
○
1.5s
P08.01
The arrival time of
S-curve
deceleration
setting 1
0.0~50.0s
0.0~50.0
○
1.5s
P08.02
The start time of
S-curve stopping
setting
0.0~50.0s
0.0~50.0
○
1.5s
P08.03
The arrival time of
S-curve stopping
setting
0.0~50.0s
0.0~50.0
○
1.5s
P08.04
The arrival time of
S-curve
deceleration
setting 2
0.0~50.0s
0.0~50.0
○
1.5s
P08.05
Forced stopping
time
0.0~3600.0s
0.0~3600.0
○
1.5s
Actual acceleration time =P00.11+ (P01.06+P01.07)/2
Actual deceleration time =P00.12+ (P08.06+P08.01)/2
After the inverter receives the stop command
Actual re-deceleration time =P08.04+ (P08.02+P08.03)/2
3.
Start-Stop control
Function
code
Name
Description
Setting
Range
Modify
Factory
setting
P01.00
Start
running
form
0:Start-up directly
1:Start-up after DC braking
2:Start-up after speed tracking
1.
3:Start-up after speed tracking
2
0~3
○
0