![INVT GD200L-004G-4 Operation Manual Download Page 49](http://html1.mh-extra.com/html/invt/gd200l-004g-4/gd200l-004g-4_operation-manual_2085737049.webp)
Goodrive200L
inverters Function parameters
44
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
Setting range: 20.0%~120.0%
P02.28
Correction
coefficient of
motor 1
power
Correct the power displaying of motor 1.
Only impact the displaying value other than the
control performance of the inverter.
Setting range: 0.00~3.00
1.00
●
P03 Group Vector control
P03.00
ASR speed
proportion
gain 1
The parameters P03.00~P03.05 only apply to
vector control mode. Below the switching
frequency 1(P03.02), the speed loop PI
parameters are: P03.00 and P03.01. Above the
switching frequency 2(P03.05), the speed loop PI
parameters are: P03.03 and P03.04. PI
parameters are gained according to the linear
change of two groups of parameters. It is shown
as below:
PI parameters
Output frequency
(P03.00,P03.01)
(P03.03,P03.04)
P03.02
P03.05
Setting the proportional coefficient and integral
time of the adjustor can change the dynamic
response performance of vector control speed
loop. Increasing the proportional gain and
decreasing the integral time can speed up the
dynamic response of the speed loop. But too high
proportional gain and too low integral time may
cause system vibration and overshoot. Too low
proportional gain may cause system vibration
and speed static deviation.
PI has a close relationship with the inertia of the
system. Adjust on the base of PI according to
20.0
○
P03.01
ASR speed
integral time
1
0.200s
○
P03.02
Switch low
point
frequency
5.00Hz
○
P03.03
ASR speed
proportion
gain 2
20.0
○
P03.04
ASR speed
integral time
2
0.200s
○
P03.05
Switch high
point
frequency