![INVT GD200L-004G-4 Operation Manual Download Page 64](http://html1.mh-extra.com/html/invt/gd200l-004g-4/gd200l-004g-4_operation-manual_2085737064.webp)
Goodrive200L
inverters Function parameters
59
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
1:Counter input, high-speed pulse counter input
terminals
2:Length counting input, length counter input
terminals
P05.50
Lower limit
frequency of
HDI
0.000kHz~P05.52
0.000
kHz
○
P05.51
Correspondin
g setting of
HDI low
frequency
setting
-100.0%~100.0%
0.0%
○
P05.52
Upper limit
frequency of
HDI
P05.50 ~50.00kHz
50.00
kHz
○
P05.53
Correspondin
g setting of
upper limit
frequency of
HDI
-100.0%~100.0%
100.0%
○
P05.54
HDI
frequency
input filter
time
0.000s~10.000s
0.100s
○
P06 Group Output terminals
P06.00 HDO output
The function selection of the high-speed pulse
output terminals.
0: Open collector pole high speed pulse output:
The Max.pulse frequency is 50.0kHz. See
P06.27~P06.31 for detailed information of the
related functions.
1: Open collector pole output. See P06.02 for
detailed information of the related functions.
0
◎
P06.01
Y1 output 0:Invalid
1:In operation
2:Forward rotation
3:Reverse rotation
4: Jogging
5:The inverter fault
6:Frequency degree test FDT1
0
○
P06.02 HDO output
0
○
P06.03
Relay RO1
output
1
○
P06.04
Relay RO2
output
5
○