Goodrive200L
inverters Basic operation instruction
117
Function
code
Name
Description
Range
Modify
Factory
setting
P06.02
HDO output
selection
2: Forward rotation
3: Reversal rotation
5:Inverter fault
6:The detection of
frequency level FDT1
7:The detection of
frequency level FDT2
14:Overload forewarning
27: Under the emergency
running state, please
change the direction of
motor.
(P01.30 is valid)
29: SPI fault output
detection
0~30
○
29
P06.03
RO1 relay
output
selection
0~30
○
1(Output
connects to
the running
contactor. )
P06.04
RO2 relay
output
selection
0~30
○
6(Output
connects to
the braking
contactor.)
P6.05
Polarity
selection of
output
terminals
0: The input terminals are
polarity.
1: The input terminals are
negative polarity.
2: Inverse HDO
0-0F
03
P08.32
FDT1 level
detection
value
0.00~P00.03(Max
frequency)
0.00~
P00.0
3
○
0.10Hz
P08.33
FDT1 lag
detection
value
0.0~100.0%(FDT1 level)
0.0~1
00.0
○
0.0%
P01.26
Feedback
Signal
selection of
running
contactor
0:Signal of running
contactor feedback is
invalid.
1:Signal of running
contactor feedback is valid.
2: Detection feedback
signal missing doesn’t call
fault. The inverter testing
contactor feedback signal,
when inspection feedback
signal and the time beyond
P01.27 feedback check out
time, inverter stop but no
RE code.
0~2
○
0