Goodrive200L
inverters Function parameters
29
Function Parameters 6
6.1 What this chapter contains
This chapter lists and describes the function parameters.
6.2 Goodrive200L general series function parameters
The function parameters of Goodrive200L series inverters have been divided into 30 groups
(P00~P29) according to the function, of which P18~P28 are reserved. Each function group
contains certain function codes applying 3-level menus. For example, “P08.08” means the
eighth function code in the P8 group function, P29 group is factory reserved, and users are
forbidden to access these parameters.
For the convenience of function codes setting, the function group number corresponds to the
first level menu, the function code corresponds to the second level menu and the function
code corresponds to the third level menu.
1.
Below is the instruction of the function lists:
The first line
“Function code”: codes of function parameter group and parameters;
The second line
“Name”: full name of function parameters;
The third line
“Detailed illustration of parameters”: detailed illustration of the function
parameters;
The fourth line
“Default value”: the original factory set value of the function parameter;
The fifth line
“Modify”: the modifying character of function codes (the parameters can be
modified or not and the modifying conditions), below is the instruction:
“
○
”: means the set value of the parameter can be modified on stop and running state;
“
◎
”: means the set value of the parameter can not be modified on the running state;
“
●
”: means the value of the parameter is the real detection value which can not be
modified.
(The inverter has limited the automatic inspection of the modifying character of the
parameters to help users avoid mismodifying).
2.
“Parameter radix” is decimal (DEC), if the parameter is expressed by hex, then the
parameter is separated from each other when editing. The setting range of certain bits are
0~F (hex).
3.
”The default value” means the function parameter will restore to the default value during
default parameters restoring. But the detected parameter or recorded value won’t be
restored.
4.
For a better parameter protection, the inverter provides password protection to the
parameters. After setting the password (set P07.00 to any non-zero number), the system will
come into the state of password verification firstly after the user press PRG/ESC to come
into the function code editing state. And then “0.0.0.0.0.” will be displayed. Unless the user
input right password, they cannot enter into the system. For the factory setting parameter
zone, it needs correct factory password (remind that the users can not modify the factory
parameters by themselves, otherwise, if the parameter setting is incorrect, damage to the
inverter may occur). If the password protection is unlocked, the user can modify the