Problem
Other symptoms
Possible cause
Solution
Documentation
Motors lose power
while driving
None
Bad connections
Switch mobility device
off, wait 10 seconds,
switch mobility device
on again. Check all
cabling.
See
Motor judders or runs
irregularly, or only
one motor runs
None
Carbon brushes worn
Check carbon brushes
and replace if
necessary
See
Bearing defective
Replacing motor
See
and
6.6.4 Replacing
Motor-Gearbox Unit
(Storm
Collector defective
Measure internal
resistance of motor,
replace motor if
defective
See
and
6.6.4 Replacing
Motor-Gearbox Unit
(Storm
Motors do not run
None
Bad connections
Check all cabling
See
Fuse burnt out
Check cabling and
replace fuse
See
and
Batteries defective
Replace batteries
See
Cabling to power
module or remote
defective
Check cabling
See
Power module
defective
Replace power module
See
LiNX power module
bracket, page 60
or
True Trac Plus power
module, page 60
Corroded contacts
Water, salt or urine
has penetrated
Check cabling, replace
if necessary
See
Motor makes clicking
noise
None
Bearing defective
Replacing motor
See
Collector defective
Measure internal
resistance of motor,
replace motor if
defective
See
and
6.6.4 Replacing
Motor-Gearbox Unit
(Storm
.
Scraping noise or
motor blocked
None
Bearing defective
Replacing motor
See
Gearbox defective
Replace gearbox
See
and
1533060-N