Data Communications and Operating Options
5-15
5
Use these commands to modify the virtual display:
Command
Result
Review
Moves the display up one row in the current virtual display
image if a display control sequence was executed.
Forward
Moves the display image down one row in the current virtual
display image following a review command.
Backspace
Can cause the default display position to be moved up one row
in the current virtual display image if (1) display overflow has
occurred since the last erase display control sequence, and (2)
the command is executed with the cursor in the first column of
the last display row.
Clear
Executes multiple backspaces. Can also cause the default
display position to be moved up one or more rows in the
current virtual display image.
Displaying ASCII Control Codes
The reader uses a center dot to display ASCII control code characters such as
CR LF. The center dot is a unique programmed character distinguishable from
all other ASCII characters.
The reader displays prompting configuration and IRL display control
characters as a sequence of characters that can be displayed. Two to five
characters can be used to display one control code. For example, the line feed
control code could be displayed as
<
LF
>
or LF.
Displaying Data on a Terminal
When you connect the 9560 to a CRT terminal, you need to set the type of
terminal operation. Typically, you set the display to match the reader’s
terminal setting. Your choices as are follows:
•
Buffered (default)
•
Transparent
•
Nonbuffered, full-duplex
•
Nonbuffered, half-duplex
•
Block
Summary of Contents for Transaction Manager 9560
Page 1: ...nugget c o d e 3 9 helconital 9560TransactionManager P N 059724 005 User s Manual...
Page 4: ......
Page 14: ......
Page 22: ...nugget c o d e 3 9 helconital...
Page 28: ......
Page 30: ...nugget c o d e 3 9 helconital...
Page 48: ...nugget c o d e 3 9 helconital...
Page 62: ......
Page 64: ...nugget c o d e 3 9 helconital...
Page 76: ...nugget c o d e 3 9 helconital...
Page 108: ...nugget c o d e 3 9 helconital...
Page 132: ......
Page 134: ......
Page 191: ...Configuration Commands UPC EAN 7 59 7 6 Scan this label Exit Configuration Save Settings...
Page 194: ......
Page 196: ...nugget c o d e 3 9 helconital...
Page 226: ......
Page 228: ...nugget c o d e 3 9 helconital...
Page 246: ......
Page 248: ...nugget c o d e 3 9 helconital...
Page 254: ......
Page 256: ...nugget c o d e 3 9 helconital...
Page 262: ......
Page 264: ......
Page 272: ......
Page 278: ......
Page 280: ......
Page 298: ......
Page 308: ......