Getting Started
27
Table 3.
RAID Level, Hard Drives, and Usable Storage Capacity
RAID Level
Available
Capacity with
2 Hard Drives*
Available
Capacity with
3 Hard Drives*
Available
Capacity with
4 Hard Drives*
Available
Capacity with
5 Hard Drives*
RAID 0
2 GB
3 GB
4 GB
5 GB
RAID 1
1 GB
1 GB
1 GB
1 GB
RAID 4
NA
2 GB
3 GB
4 GB
RAID 5
NA
2 GB
3 GB
4 GB
RAID 10
NA
NA
2 GB
NA
* Each hard drive is assumed to have 1 GB capacity.
Are Hot Fix Drives Needed?
Assume that one of the hard drives of the RAID 5 disk array fails (Hot Fix drives are available with
RAID 1, 4, 5, and 10 arrays). The disk array is without redundancy. Time Without Redundancy
(TWR) starts to run. Any unnecessary prolongation of the TWR (the time required to get a
replacement drive, or because you did not immediately recognize the failure) increases the risk of
data loss that will occur should a second drive fail. Therefore, redundancy should be restored as
soon as possible and in an automated manner. Integrating a Hot Fix drive (also referred to as hot
spare) as an immediately available and auto-replacing drive is the most effective way to keep the
TWR as short as possible. Only a Hot Fix drive can ensure optimal disk array security and constant
data availability.
Using a Hot Fix drive is not compulsory. If you control the disk array at regular intervals and
immediately replace a defective drive (by shutting down the system or hot-plugging), you can
operate the system without a Hot Fix drive.
Intel RAID Controller Hardware Features
This section provides a summary of the key features, configuration options and support interface
technology supported by the IIR controller.
Architecture Features (HW)
Table 4.
Hardware Architecture
Component Feature
I/O Microprocessor
The 80303 uses the 100MHz Intel 80960JT-100 core with a
100MHz/64-bit internal bus
with an internal throughput of up to
800MB/sec,
to and from the internal IOP peripherals.
Cache Memory
The SRCU32 supports up to 256MB of 64-bit ECC SDRAM
operating at 100MHz. Memory is expandable to 64, 128, or 256MB.
Flash Memory
3.3v, 16Mb (2MB) flash memory chip is used to store the RAID
firmware
I/O interface (PCI)
PCI 2.2 compliant, universally keyed for 3.3 and 5 volt PCI slots
PCI Transfer Rate
528MB/sec (Burst)
PCI Signaling
5 or 3.3 volt
SCSI Controller: LSI SYM53C1010
Dual channel Ultra160
Summary of Contents for SRCU32 - RAID Controller
Page 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Page 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Page 46: ......
Page 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Page 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Page 122: ......
Page 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Page 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Page 170: ...170 Intel RAID Controller SRCU32 User s Guide ...