32
Intel RAID Controller SRCU32 User’s Guide
External LED Connectors
The IIR Controller has a 6 pin header to allow for connection of additional LEDs. An LED
connected with header A lights up whenever there is activity on SCSI channel A. The same applies
for header B. An LED connected with the SUM header lights up whenever there is activity on any
of the two SCSI channels A and B. See Figure 8 for details.
Figure 8. External LED Connectors
Terminator Power
Determines whether termination power (per channel) is supplied by the controller. The Default is
ON for both channels (both jumpers set).
Acoustical Alarm
An acoustical (audible) alarm is present on the RAID controller to indicate any of the following
events:
•
State of controller upon boot-up
•
Change in state of array
•
Change controller environmental status (during normal operation)
•
Hardware failure
If the cause of the event is resolved and/or removed, the audible alarm will cease. The audible
alarm can also be turned off manually through StorCon or StorCon plus. If the audible alarm is
silenced via management tools, it will only be disabled for the current event and will be ready to
sound again at the next event.
Silencing the Acoustical Alarm in StorCon
An option is available in StorCon under Advanced Setup
!
Configure Controller, press <F4> to
silence alarm. The <F4> option is available only if the alarm has been activated.
Silencing the Acoustical Alarm in
To silence the alarm in , in the “Physical Configuration” view, right-click on the icon for
the controller that requires alarm deactivation. Click on “Silence” to deactivate the alarm. If the
alarm has not been activated, the “Silence” option will be grayed out and unavailable.
Summary of Contents for SRCU32 - RAID Controller
Page 1: ...Intel RAID Controller SRCU32 User s Guide Order Number A77949 004 ...
Page 35: ...Getting Started 35 Figure 9 Operational State Diagram for RAID 4 5 ...
Page 46: ......
Page 62: ...62 Intel RAID Controller SRCU32 User s Guide ...
Page 76: ...76 Intel RAID Controller SRCU32 User s Guide ...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem ...
Page 122: ......
Page 164: ...164 Intel RAID Controller SRCU32 User s Guide Figure 106 StorCon Help ...
Page 167: ...Storage Console Plus 167 Figure 109 RAID Configuration Service Add Remove Users ...
Page 170: ...170 Intel RAID Controller SRCU32 User s Guide ...