Balanced Technology Extended (BTX) Thermal/Mechanical Design Information
Thermal and Mechanical Design Guidelines
41
5
Balanced Technology Extended
(BTX) Thermal/Mechanical
Design Information
5.1
Overview of the Balanced Technology Extended
(BTX) Reference Design
The reference thermal module assembly is a Type II BTX compliant design and is
compliant with the reference BTX motherboard keep-out and height recommendations
defined Section
The solution comes as an integrated assembly. An isometric view of the assembly is
provided Figure
5.1.1
Target Heatsink Performance
5-1 provides the target heatsink performance for the processor with the BTX
boundary conditions. The results will be evaluated using the test procedure described
in Section
The table also includes a T
A
assumption of 35.5 °C for the Intel reference thermal
solution at the processor fan heatsink inlet discussed Section
3.3. The analysis
assumes a uniform external ambient temperature to the chassis of 35 °C across the
fan inlet, resulting in a temperature rise, T
R
, of 0.5 °C. Meeting T
A
and
Ψ
CA
targets can
maximize processor performance (refer to Sections
2.4. and Chapter
Minimizing T
R
, can lead to improved acoustics.
Summary of Contents for Celeron Dual-Core E1000 Series
Page 10: ...10 Thermal and Mechanical Design Guidelines...
Page 26: ...Processor Thermal Mechanical Information 26 Thermal and Mechanical Design Guidelines...
Page 68: ...ATX Thermal Mechanical Design Information 68 Thermal and Mechanical Design Guidelines...
Page 86: ...Heatsink Clip Load Metrology 86 Thermal and Mechanical Design Guidelines...
Page 88: ...Thermal Interface Management 88 Thermal and Mechanical Design Guidelines...
Page 120: ...Legacy Fan Speed Control 120 Thermal and Mechanical Design Guidelines...
Page 126: ...Fan Performance for Reference Design 126 Thermal and Mechanical Design Guidelines...
Page 127: ...Fan Performance for Reference Design Thermal and Mechanical Design Guidelines 127...