Intel® Quiet System Technology (Intel® QST)
72
Thermal and Mechanical Design Guidelines
7.2
Board and System Implementation of Intel
®
QST
To implement the board must be configured as shown in Figure
7-3 and listed below:
•
ME system (S0-S1) with Controller Link connected and powered
•
DRAM with Channel A DIMM 0 installed and 2MB reserved for Intel
®
QST FW
execution
•
SPI Flash with sufficient space for the Intel
®
QST Firmware
•
SST-based thermal sensors to provide board thermal data for Intel
®
QST
algorithms
•
Intel
®
QST firmware
Figure
7-3. Intel
®
QST Platform Requirements
Note:
Simple Serial Transport (SST) is a single wire bus that is included in the ICH8 to
provide additional thermal and voltage sensing capability to the Intel
®
Management
Engine (ME)