Fan Performance for Reference Design
Thermal and Mechanical Design Guidelines
109
Appendix F
Fan Performance for
Reference Design
The fan power requirements for proper operation are given Table
Table
7–3. Fan Electrical Performance Requirements
Requirement Value
Maximum Average fan current draw
1.5 A
Fan start-up current draw
2.2 A
Fan start-up current draw maximum
duration
1.0 second
Fan header voltage
12 V ± 5%
Tachometer output
2 pulse per revolution
Tachometer output signal
Open-collector (open-drain)
PWM signal input frequency
21 kHz to 28 kHz
PWM signal pull up in fan
3.3 V (recommended max)
5.25 V (absolute max)
PWM signal current source
Imax = 5 mA
(short circuit current)
PWM signal maximum voltage for logic
low
VIL = 0.8 V
PWM compliant function
RPM must be within spec for specified
duty cycle
In addition to comply with overall thermal requirements (Sections
6.2), and
the general environmental reliability requirements (Sections
should meet the following performance requirements:
Mechanical wear out represents the highest risk reliability parameter for fans. The
capability of the functional mechanical elements (ball bearing, shaft, and tower
assembly) must be demonstrated to a minimum useful lifetime of 57,000 hours.
In addition to passing the environmental reliability tests described in Sections
6.3, the fan must demonstrate adequate performance after 7,500 on/off
cycles with each cycle specified as 3 minutes on, 2 minutes off, at a temperature
of 70° C.
See the
Fan Specification for 4-wire PWM Controlled Fans
for additional details on the
fan specification.
§
Summary of Contents for BX80570E8200 - Core 2 Duo 2.66 GHz Processor
Page 10: ...10 Thermal and Mechanical Design Guidelines...
Page 26: ...Processor Thermal Mechanical Information 26 Thermal and Mechanical Design Guidelines...
Page 82: ...Heatsink Clip Load Metrology 82 Thermal and Mechanical Design Guidelines...
Page 84: ...Thermal Interface Management 84 Thermal and Mechanical Design Guidelines...
Page 110: ...Fan Performance for Reference Design 110 Thermal and Mechanical Design Guidelines...