![Intel 87C196CA Supplement To User’S Manual Download Page 53](http://html1.mh-extra.com/html/intel/87c196ca/87c196ca_supplement-to-users-manual_2071580053.webp)
6-1
CHAPTER 6
SYNCHRONOUS SERIAL I/O PORT
The synchronous serial I/O (SSIO) port on the 8XC196Lx has been enhanced, implementing two
new special function registers (SSIO0_CLK and SSIO1_CLK) that allow you to select the oper-
ating mode and configure the phase and polarity of the serial clock signals.
6.1
SSIO 0 CLOCK REGISTER
The SSIO 0 clock (SSIO_CLK) register selects the phase and polarity for the SC0 clock signal.
In standard mode, SC0 is channel 0’s clock signal. In duplex and channel-select modes, SC0 is
the common clock signal for both SSIO channels.
SSIO0_CLK
Address:
Reset State:
1FB5H
00H
The SSIO 0 clock (SSIO0_CLK) register configures the serial clock for channel 0. In standard mode,
the SC0 is channel 0’s clock signal. In duplex and channel-select modes, SC0 is the common clock
signal for both SSIO channels.
7
0
—
—
—
—
—
—
PHAS
POLS
Bit
Number
Bit
Mnemonic
Function
7:2
—
Reserved; for compatibility with future devices, write zeros to these bits.
1
PHAS
Phase and Polarity Select
For normal transfers, these bits determine the idle state of the serial
clock and select the serial clock signal edge on which the SSIO samples
incoming data bits or shifts out outgoing data bits. These bits are ignored
for handshaking transfers. Use SSIO0_ CON to select the type of data
transfer (normal or handshaking) for channel 0.
For transmissions
PHAS
POLS
0
0
low idle state; shift on falling edges
0
1
high idle state; shift on rising edges
1
0
low idle state; shift on rising edges
1
1
high idle state; shift on falling edges
For receptions
PHAS
POLS
0
0
low idle state; sample on rising edges
0
1
high idle state; sample on falling edges
1
0
low idle state; sample on falling edges
1
1
high idle state; sample on rising edges
0
POLS
Figure 6-1. SSIO 0 Clock (SSIO0_CLK) Register
Summary of Contents for 87C196CA
Page 9: ...1 Guide to This Manual...
Page 10: ......
Page 13: ...2 Architectural Overview...
Page 14: ......
Page 22: ......
Page 23: ...3 Address Space...
Page 24: ......
Page 33: ...4 Standard and PTS Interrupts...
Page 34: ......
Page 43: ...5 I O Ports...
Page 44: ......
Page 51: ...6 Synchronous Serial I O Port...
Page 52: ......
Page 56: ......
Page 57: ...7 Event Processor Array...
Page 58: ......
Page 65: ...8 J1850 Communications Controller...
Page 66: ......
Page 89: ...9 Minimum Hardware Considerations...
Page 90: ......
Page 93: ...10 Special Operating Modes...
Page 94: ......
Page 98: ......
Page 99: ...11 Programming the Nonvolatile Memory...
Page 100: ......
Page 106: ......
Page 107: ...A Signal Descriptions...
Page 108: ......
Page 118: ......
Page 119: ...Glossary...
Page 120: ......
Page 133: ...Index...
Page 134: ......