4.
Suspend the transformer from the plate. This operation must be carried out between two people.
5.
Screw on the bottom attachment.
6.
Check that the transformer is secured well.
Fixing the unit to the transformer
7.
Suspend the inverter on the transformer by fitting the holes in the former onto the lugs at the top of the
transformer.
8.
Adjust the two housings so that their edges coincide and are parallel, so that the drilled plates at the rear
bottom right of the inverter and the front bottom right part of the transformer are in contact and their drilled parts
coincide.
9.
To join the inverter and transformer together, the choice can be made between a nut and bolt or the use of
a padlock.
Unit-to-transformer junction
AAY2000IKI04
27
Installation manual
Ingeteam Power Technology, S.A.
Summary of Contents for Ingecon mWind 2.5