Screen 2
Vdc
Voltage supplied by the wind generator to the inverter (V).
Idc
Current supplied by the wind generator to the inverter (A).
Screen 3
Alarm
Status of inverter alarms. The installer has instructions for the proper response to each alarm. Only the
ones mentioned in this manual may be of use to the user.
0000H
No alarms.
0001H
Insufficient input voltage.
0002H
Grid frequency out of range.
0004H
Grid voltage out of range.
0008H
Overcurrent in the inverter bridge.
0010H
Overcurrent in the AC/DC converter.
0020H
Insulation fault.
0040H
Grid overcurrent.
0080H
Overtemperature.
0100H
Bus overvoltage.
0200H
Configuration change.
0400H
Manual shutdown.
0800H
HW error.
1000H
Instantaneous grid overcurrent.
2000H
Detection of island mode operation.
4000H
Relay impedance out of range.
8000H
Hardware fault alert.
The value displayed in “Alarm Inv” can be the result of the (hexadecimal) sum of two or more of the
values listed above.
For example: Alarm Inv 0006H means the grid frequency and voltage are out of range (0002H +
0004H).
NumInv
Number allocated to the inverter through the menu accessible in the display for identifying
communications.
Code1
Unit operating code. This can be requested from Ingeteam’s customer services.
Code2
Unit operating code. This can be requested from Ingeteam’s customer services.
SN
Serial Number.
Screen 4
TotE
Total energy (kWh) delivered by the inverter to the grid from the date it was manufactured. Recording
the serial number of the equipment marks the start of this power log.
T con
Number of hours the inverter has been connected to the grid.
NumCon
Number of grid connections made during all hours of operation.
Screen 5
ETotal
Total energy (kWh) delivered by the inverter to the grid since the last time the counter was reset.
T con
Number of hours the inverter has been connected to the grid since the counter was last reset.
NumCon
Number of grid connections since counter was last reset.
Screen 6
FW Ver.
Unit firmware version.
DFW Ver.
Unit display firmware version.
D. Boot
Version of the display program enabling firmware housing.
AAY2000IKI04
41
Installation manual
Ingeteam Power Technology, S.A.