Wind generator with AC output and built-in braking system
In this case an AC-DC conversion system will be required to change the generator output voltage to DC.
wind generator
grid
conversion system
Ingecon
®
μWind
AC
AC
DC
Wind generator with DC output with no built-in braking system
An external braking system is needed to be able to stop the wind generator or reduce the angular velocity.
wind generator
heating resistor
grid
braking system
Ingecon
®
μWind
DC
AC
DC
Wind generator with AC output with no built-in braking system
An external braking system is needed to be able to stop the wind generator or reduce itsangular velocity, as well as
another system to convert from AC to DC before the current reaches the Ingecon
®
μWind unit.
wind generator
heating resistor
grid
braking and conversion system
Ingecon
®
μWind
AC
AC
DC
AAY2000IKI04
10
Installation manual
Ingeteam Power Technology, S.A.