Installation / Assembly
T-Rack
®
3.0 Series
– Assembly Instructions 1.1(2019-03) E inge
Page 65 of 84
© inge GmbH
5.14.3 Attaching Connectors
Options
Option
Article no.
Article designation
Purpose
KT-0162
Flange Adapter Cap DN
150 x 6‘‘ for connection
from 6‘‘ grooved coupling
systems
Connection of 6" grooved coupling system to
flange with connection dimensions according to
ISO 7005 PN 10, ANSI Class 150
KT-0163
Blind Cap 6‘‘
for grooved coupling
systems
Closing of feed and filtrate headers
KT-0164
Blind Cap 6‘‘ with G2‘‘
Thread for grooved
coupling systems
Connection of equipment for venting, measuring,
etc.,
G2” female thread according to
DIN ISO 228 BSPP
The connectors are attached using original flexible composite
couplings 6” from inge
®
.
Step
Activity
Figure
1
Lubricate the gaskets with glycerin
a)
Remove the gaskets of the flexible composite
couplings 6”.
b)
Lubricate the gaskets with glycerin on the inside and
outside.
2
Mount the gasket on the end pipe
a)
Remove the protective cap from the corresponding pipe.
b)
Mount one of the lubricated gaskets over the opening of the
corresponding end pipe.
c)
Push the gasket onto the corresponding pipe so it is flush
with the end of the pipe.