15
• DOK-POWER*-TVD*1.3****-ANW1-EN-E1,44 • 02.97
3. Electrical Connections
3.1. Interconnect diagram TVD 1.3 with NAM 1.3
L-
L+
+ -
2L+
X 7
X7
R2
X16
UD
BB
+15V
0VM
-15V
+24V
0VL
UESS
shield
Bb1
UD
BVW
TVW
ZKS
ZKS
OFF
OFF
ON
ON
+15VM
0VM
-15VM
3xAC (380 - 480) V
(50 - 60) Hz
PE
L3
L2
L1
power
supply
electronics
supply
2U1
2V1
2W1
1U1
1V1
1W1
EPU+
EPU -
PE
K1
1
2
3, 4
5, 6, 7, 8
9, 10
11, 12
13, 14
15
16
NCB
X 2
X 3
X 4
X 5
X 12
X 9
X1
Q1
K1
K1
1L+
2L+
EB
IB
RB1
RB2
1
2
3
4
5
6
1
2
3
4
5
6
7
8
1
2
3
4
C1
R1
EB
C2
TBM
U1
W1
V1
U2
W2
V2
NAM 1.3
1L+
X1
11,12
13,14
+24V
0VL
X7/EB
L-
L+
X7
X7
X 8
PN
X8
P
N
X 7
+24V 0V
X15
12
TVD 1.3
Supply module for direct connection of the
mains
- with built-in bleeder
- with regulated DC bus
central ground point
for all drive modules
Power
supply
for AC
drives
and/or
main
spindle
drives
DC 300V
conductor rails
Electronics
power
source,
signal
exchange,
16-pin
bus
connection
ready
bleeder prewarning
temp. prewarning
acknowledge power of
f
acknowledge power on
ZKS
OFF
ON
Options
R1 - Bleeder
can be mounted externally
R2 - auxiliary bleeder module
TBM
C1 - additional electronics backup
C2 - additional power buf
fer
max. 2
A
NC regulated braking
max. 100 mA
power voltage ok
NAM - power connection module
BR1 - bridge for switching bleeder
Circuit diagram for a TVD 1.3 with mains connection module NAM 1.3
with 380 ... 480V supply connection and internal electronics - internal power switch
1
2
3
4
5
6
+24V
0VL
7
8
BR1
- +
from
TVD connector X1:
16-pin bus connection
for blower supply
for TBM
with
DC 24V blower
power
TVD12/NAM12Anschlpl
shield
Fig. 3.1:
Interconnect diagram -TVD 1.3 supply module with NAM 1.3