12
• DOK-POWER*-TVD*1.3****-ANW1-EN-E1,44 • 02.97
2. Range of Applications
2.4. Technical Data - TVD 1.3
Designation
Symbol Unit TVD 1.3-15-3 TVD 1.3-08-3
Power section
Input voltage
U(ACN)
(V)
3 x 380 ... 480 (
±
10%)
Frequency
f(N)
(Hz)
50 ...60
DC bus voltage
U(DC)
(V)
320 (
±
5%)
Continuous DC bus power
P(DC)
(kW)
15
7.5
Peak DC bus power (for 0.3 s)
P(KB-03)
(kW)
45
22.5
Bleeder continuous power
P(BD)
(kW)
1
0.5
Bleeder peak power
P(BM)
(kW)
40
20
Maximum regenerated energy
W(max)
(kWs)
60
30
Power dissipation with maximum power
(without bleeder loss)
P(v)
(W)
330
180
Basic loss
(W)
75
Power loss per kW continuous
DC bus power
17
14
Weight
m
(kg)
11,2
10.5
Electronics supply
Input voltage
U(AC)
(V)
3 x 380 ... 480 (
±
10%)
Frequency
f(N)
(Hz)
50 ... 60
Incomming power
S(el)
(VA)
300
Control voltage output
+ 24V load voltage
U(L)
(V)
22 ... 26
+ 24VL continuous current
I(UL)
(A)
7.5
+ 24VL ripple
(%)
2
±
15V measuring voltage
U(M)
(V)
14.9 ... 15.1
+ 15VM continuous current
I(+UM)
(A)
2.5
- 15VM continuous current
I(-UM)
(A)
1.5 (2.0)
1)
±
15VM ripple
(%)
0.1
Ambient conditions
Permissible ambient temperature
with rated data
T(um)
(
°
C)
+5 ... +45
Maximum permissible ambient temperature
with derated data
T(umr)
(
°
C)
55
Storage and transport temperatures
T(L)
(
°
C)
-30 ... +85
Installation elevation with derating
max. 1000 meters above sea level
Permissible relative humidity
max. 95%
Permissible absolute humidity
25g water / m
3
Luft
Protection category
IP 10 per DIN 40 050
Contamination level
non-conductive dirt, no condensate
Suitable auxilary units
NAM 1.3-15
NAM 1.3-08
1)
The -15VM can be loaded with a maximum of 2 A.
The load of + 15VM and - 15VM combined may not exceed 4 A.
Fig. 2.4: Technical data of supply module TVD 1.3