34
• DOK-POWER*-TVD*1.3****-ANW1-EN-E1,44 • 02.97
3. Electrical Connections
3.22. Front view of the TVD 1.3
Typ:
Serien-Nr.:
X1
POWER SUPPLY
TM
X2
X3
X4
P N
X5
FATVD12Ver
X9
L+
L-
S2
RESET
X7
X7
Terminal block for
mains and DC bus
reactor
connections
DC bus for
the power
supply of the
drives
PE-conductors
central ground
for each drive
controller
Connection
of bus cable
of signal voltage
supply and drive
monitoring
RESET key
Diagnostics Display
Plug-in terminals for:
• control inputs
• status messages
• 24V,
±
15V outputs
Bridge capacitor
connection
Fig. 3.19: Front view of supply module TVD 1.3