6.3 Initializing the Settings of this Product
HDK-97C 1303 VER1 (U)
107
TROUB
L
E SH
O
O
TING an
d MAINTE
NAN
CE
6
6.3 Initializing the Setting
s
of thi
s
Product
The following two cases are available for initializing the setting of this product.
①
Initializes the camera back to the user setting (ENGINEER SET FILE).
This initializes the camera back to the state set by user engineer in advance in response to the environment and the shooting
conditions.
②
Initializes the camera back to the initial factory setting (FACTORY SET FILE)
This initializes the camera back to the initial factory setting.
To change the settings, select "PRESET FILE LOAD" on MENU (3/3), then "FILE SELECT" and "LOAD START".
The following explains the set values, descriptions, and setting procedures.
Set Value
De
s
cription
FILE SELECT
ENGINEER (default) Initializes the state back to the user setting.
FACTORY
Initializes the state back to the initial factory setting.
LOAD START
READY (default)
The state before initialization
START
Starts initialization.
CANCEL
Cancels initialization.
1
On MENU (3/3), turn the rotary pulse switch to
position the cursor on "PRESET FILE LOAD", and
press the SET button.
The submenu is displayed.
SCAN FORMAT SELECT
CPU SYSTEM CONTROL
AUTO IRIS SET
AUTO SETUP MODE
LENS SELECT
LEVEL ADJUST
PROCESS MODE
PRESET FILE LOAD
*** MENU (3/3) ***
▲
▲
▲
①
Position the cursor on
"PRESET FILE LOAD"
and confirm.
2
Turn the rotary pulse switch to position the cursor
on "FILE SELECT", and press the SET button.
The cursor moves to the mode selection column.
FILE SELECT ENGINEER
LOAD START READY
PRESET FILE LOAD
▲
②
Position the cursor on
"FILE SELECT" and
confirm.
3
Turn the rotary pulse switch to select the value to
be set, and press the SET button.
The value is con
fi
rmed.
FILE SELECT ENGINEER
LOAD START READY
PRESET FILE LOAD
▲
③
Select "ENGINEER"
or "FACTORY" and
confirm.
4
Press the SET button when the cursor
automatically moves to "LOAD START".
The cursor moves to the mode selection column and
its display changes from "READY" to "START".
FILE SELECT ENGINEER
LOAD START READY
PRESET FILE LOAD
▲
④
Position the cursor on
"LOAD START" and
confirm.
Summary of Contents for FA-97
Page 1: ...3G HIGH DEFINITION CAMERA SYSTEM HDK 97C FA 97 OPERATION MANUAL...
Page 2: ......
Page 17: ...1 OUTLINE...
Page 18: ...2 HDK 97C 1303 VER1 U...
Page 26: ......
Page 27: ...2 NAME and FUNCTION...
Page 28: ...12 HDK 97C 1303 VER1 U...
Page 47: ...3 INSTALLATION and CONNECTION...
Page 48: ...32 HDK 97C 1303 VER1 U...
Page 50: ...3 1 Preparation 34 HDK 97C 1303 VER1 U...
Page 52: ......
Page 54: ......
Page 70: ...54 HDK 97C 1303 VER1 U...
Page 71: ...4 OPERATION...
Page 72: ...56 HDK 97C 1303 VER1 U...
Page 89: ...5 CAMERA SETTINGS and ADJUSTMENT...
Page 90: ...74 HDK 97C 1303 VER1 U...
Page 119: ...6 TROUBLE SHOOTING and MAINTENANCE...
Page 120: ...104 HDK 97C 1303 VER1 U...
Page 129: ...7 SPECIFICATIONS...
Page 130: ...114 HDK 97C 1303 VER1 U...
Page 134: ...7 2 External Dimensions Diagram 118 HDK 97C 1303 VER1 U Left View 94 3 7 1 337 5 270 5...
Page 136: ...7 2 External Dimensions Diagram 120 HDK 97C 1303 VER1 U Rear View 138 5 3...
Page 152: ...136 HDK 97C 1303 VER1 U...
Page 154: ......
Page 155: ......