5.2 Settings from the Menu
HDK-97C 1303 VER1 (U)
93
C
A
ME
R
A
SE
T
T
INGS an
d AD
JUS
T
ME
NT
5
3
On MENU (3/4), turn the rotary pulse switch
to position the cursor on "LENS SELECT," and
press the SET button.
The submenu is displayed.
SCAN FORMAT SELECT
CPU SYSTEM CONTROL
AUTO IRIS SET
AUTO SETUP MODE
LENS SELECT
LEVEL ADJUST
PROCESS MODE
CUSTOM GAMMA DATA
PRESET FILE LOAD
*** MENU (3/3) ***
▲
▲
▲
③
Position the flashing
cursor on "LENS
SELECT" and confirm.
4
Set "NUMBER", "NAME" and "EXTENDER".
Refer to the explanation of corresponding item for
how to set each data.
NO. 1 is selected here as an example.
CAUTION:
If a new
fi
le is created with the same
fi
le number as an existing
fi
le, the data will be overwritten and the old data will be lost.
5
Turn the rotary pulse switch to position the cursor
on "FILE SET," and press the SET button.
The cursor moves to the mode selection column.
FILE SET
OFF
LENS NO.1
PUSH SET→START
NUMBER
NO.1
NAME ( )
(AB40X10 ABCD )
EXTENDER
OFF
AUTO SEL
OFF
FILE SET
OFF
LENS TYPE
***
AUTO X0.8 CONV
OFF
LENS SERIAL I/F
OFF
LENS SELECT
▲
⑤
Position the cursor on
"FILE SET" and
confirm.
⑥
Select the set value
and confirm.
⑦
Either message is
displayed or flashes.
6
Turn the rotary pulse switch to select the set
value, and press the SET button.
The value is con
fi
rmed, and either of the following
messages is displayed at the bottom of the screen:
- LENS No. x
: Displayed when "MANUAL"
is selected.
- PUSH SET -> START : Displayed and
fl
ashes when
"AUTO" is selected.
Go to Step 7 when "AUTO" is selected.
When "MANUAL" is selected, go to Step M1 to
obtain the model name of the lens after lens
fi
le items
such as GAIN/FLARE/GAMMA are adjusted by
MCP, etc.
7
Press the SET button.
The lens
fi
le is created.
8
Set the S11-4 DIP switch of the MPU module back to "OFF."
Note:
- When the camera is powered OFF, the FILE SET settings are turned OFF.
- Before creating lens
fi
les, prepare all the lenses to use. Then, create the
fi
les under the same condition at a time. If the conditions are
changed, the setting cannot be accurate. Lens
fi
les memorize a difference in level between lenses. If the lighting or chart is changed, it
cannot tell whether it is the lighting error, chart error, or lens error.
Summary of Contents for FA-97
Page 1: ...3G HIGH DEFINITION CAMERA SYSTEM HDK 97C FA 97 OPERATION MANUAL...
Page 2: ......
Page 17: ...1 OUTLINE...
Page 18: ...2 HDK 97C 1303 VER1 U...
Page 26: ......
Page 27: ...2 NAME and FUNCTION...
Page 28: ...12 HDK 97C 1303 VER1 U...
Page 47: ...3 INSTALLATION and CONNECTION...
Page 48: ...32 HDK 97C 1303 VER1 U...
Page 50: ...3 1 Preparation 34 HDK 97C 1303 VER1 U...
Page 52: ......
Page 54: ......
Page 70: ...54 HDK 97C 1303 VER1 U...
Page 71: ...4 OPERATION...
Page 72: ...56 HDK 97C 1303 VER1 U...
Page 89: ...5 CAMERA SETTINGS and ADJUSTMENT...
Page 90: ...74 HDK 97C 1303 VER1 U...
Page 119: ...6 TROUBLE SHOOTING and MAINTENANCE...
Page 120: ...104 HDK 97C 1303 VER1 U...
Page 129: ...7 SPECIFICATIONS...
Page 130: ...114 HDK 97C 1303 VER1 U...
Page 134: ...7 2 External Dimensions Diagram 118 HDK 97C 1303 VER1 U Left View 94 3 7 1 337 5 270 5...
Page 136: ...7 2 External Dimensions Diagram 120 HDK 97C 1303 VER1 U Rear View 138 5 3...
Page 152: ...136 HDK 97C 1303 VER1 U...
Page 154: ......
Page 155: ......