SmartPLC DataLine with EtherNet/IP device interface
192
>
Integrate the Device into the EtherNet/IP project
41492
Preparations
►
Connect the device via the field bus interface (X6/X7) with the I/O scanner
►
Activate the top-down configuration mode (→
Set the configuration mode
(→ S.
►
Register the EDS file (→
Registration of the EDS file
)).
1 Open / create EtherNet/IP project
►
Start RSLogix 5000.
►
Open an existing EtherNet/IP project.
OR
Create a new EtherNet/IP project with EtherNet/IP controller and IO scanner.
2 Add AC1423/24 to the project
►
In the Controller Organizer: Right mouse click on IO scanners
>
Context menu appears.
►
In the context menu: Select [New Module].
>
The window [Select Module Type] appears.
►
Select the device and click on [Create].
>
The [New Module] window appears.
►
Enter name and IP address of the AC1423/24.
3 Configure module definition
►
In the window [New Module]: Click on [Change ...]
>
The [Module Definition] window appears.
►
Select the value [Compatible Module] in the [Electronic Keying] list.
►
In the [Name] column: Select [Exclusive Owner].
►
Click on [OK] to adopt the entered values.
►
Click on [OK] to add the device to the project.
>
RSLogix 5000 adds the device as a sub-element of the IO scanner to the project.