40
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
System description
Software description
>
SERIAL_MODE
1085
The serial interface is available for the exchange of data in the application. Debugging the application
software is then only possible via the CAN interface.
This function is switched off as standard (FALSE). Via the flag SERIAL_MODE the state can be
controlled and queried via the application program or the programming system.
→
chapter
Function elements: serial interface
(
>
DEBUG mode
1086
If the input DEBUG of
SET_DEBUG
(
) is set to TRUE, the programming system or the
downloader, for example, can communicate with the controller and execute some special system
commands (e.g. for service functions via the GSM modem CANremote).
In this operating mode a software download is not possible because the test input (
→ chapter
TEST
mode
) is not connected to supply voltage.