122
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
ifm function elements
ifm function elements for the device CR0301
>
5.2.8
Function elements: processing input values
INPUT_ANALOG ............................................................................................................................... 123
INPUT_CURRENT ............................................................................................................................ 125
INPUT_VOLTAGE ............................................................................................................................. 126
1602
1302
In this chapter we show you
ifm
FBs which allow you to read and process the analogue or digital
signals at the device input.
NOTE
The analogue raw values shown in the PLC configuration of CODESYS directly come from the ADC.
They are not yet corrected!
Therefore different raw values can appear in the PLC configuration for identical devices.
Error correction and normalisation are only carried out by ifm function blocks. The function blocks
provide the corrected value.