Configurations
Set up the runtime system
>
4.1.2
Update the runtime system
13269
An older runtime system is already installed on the device. Now, you would like to update the runtime
system on the device?
14158
NOTICE
Risk of data loss!
When deleting or updating the runtime system all data and programs on the device are deleted.
► Save all required data and programs before deleting or updating the runtime system!
For this operation, the same instructions apply as in the previous chapter 'Reinstall the runtime
system'.
>
4.1.3
Verify the installation
14512
14406
► After loading of the runtime system into the controller:
• check whether the runtime system was transmitted correctly!
• check whether the right runtime system is on the controller!
► 1st check:
use the
ifm
downloader or the maintenance tool to verify whether the correct version of the
runtime system was loaded:
• read out the name, version and CRC of the runtime system in the device!
• Manually compare this information with the target data!
► 2nd check (optional):
verify in the application program whether the correct version of the runtime system was loaded:
• read out the name and version of the runtime system in the device!
• Compare this data with the specified values!
The following FB serves for reading the data:
GET_IDENTITY
(→ page
Reads the specific identifications stored in the device:
• hardware name and hardware version of the device
• name of the runtime system in the device
• version and revision no. of the runtime system in the device
• name of the application (has previously been saved by means of
SET_IDENTITY
(→ page
► If the application detects an incorrect version of a runtime system:
bring all safety functions into the safe state.