182
ifm
Programming Manual
ecomatmobile
CabinetController (CR0301) Runtime System V05
2016-04-21
Appendix
System flags
>
7.1.5
System flags: inputs and outputs
20986
System flags (symbol name)
Type
Description
ANALOGx
x = 0...7
WORD
Analogue input xx:
filtered A/D converter raw value (12 bits) without calibration or
standardisation
ANALOGx
x = 8...23
WORD
Binary input INxx, analogue evaluation:
ANALOG8 for IN00
...
ANALOG23 for IN15
filtered A/D converter raw value (10 bits) without calibration or
standardisation
ANALOGx
x = 24...31
WORD
Binary input DIPx, analogue evaluation:
ANALOG24 for DIP0
...
ANALOG31 for DIP7
filtered A/D converter raw value (10 bits) without calibration or
standardisation
ANALOGxy_MODE
BYTE
Operating mode of the analogue input pair:
xy = 0_4 = inputs A ANALOG4
xy = 1_5 = inputs A ANALOG5
xy = 2_6 = inputs A ANALOG6
xy = 3_7 = inputs A ANALOG7
→ chapter
Possible operating modes inputs/outputs
(
→ page
INxx
xx = 00...15
BOOL
Status on binary input xx
Requirement: input configured as binary input
(MODE = IN_DIGITAL_H or IN_DIGITAL_L)
TRUE:
Voltage on binary input > 70 % of VBBs
FALSE: Voltage on binary input < 30 % of VBBs
or: not configured as binary input
or: not correctly configured
INxx_MODE
xx = 08...11
BYTE
Operating mode of the input INxx
→ chapter
Possible operating modes inputs/outputs
(
→ page
INxy_MODE
BYTE
Operating mode of the input pair xy:
xy = 12_13 = inputs IN12 + IN13
xy = 14_15 = inputs IN14 + IN15
→ chapter
Possible operating modes inputs/outputs
(
→ page
LEDnn
BOOL
Status on LED output nn:
TRUE:LED activated
FALSE:LED deactivated
OUTxx
xx = 00...17
BOOL
Status on binary output xx:
TRUE:
output activated
FALSE: output deactivated
>
7.1.6
System flags: system
20992
System flags (symbol name)
Type
Description
DIPx
x = 0...7
BOOL
Status of the DIP switch x