260
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
Controller functions in the ecomatmobile controller
Functions for controllers
11.3.1
Function DELAY
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController:
CR2500
Function symbol:
DELAY
X
Y
T
Description
DELAY delays the output of the input value by the time T (dead-time element).
The function is used to delay an input value by the time T.
T
t
1
y
t
t = 0
Figure: Time characteristics of DELAY
NOTE
To ensure that the function works correctly, it must be called in each cycle.