22
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
Configurations
Set up programming system
POUs in the root directory
Description
PLC_CYCLE for
Controller,
CAN operation with layer 2 or as master or slave:
Determines the cycle time of the PLC in the unit.
PDM_CYCLE_MS for
PDM,
CAN operation with layer 2 or as master or slave:
Determines the cycle time of the PLC in the unit.
PLC_PRG
for Controller and PDM,
CAN operation with layer 2 or as master or slave:
Main program This is where further program elements are included.
Structure of the visualisations in the templates
(Only for PDM)
The visualisations are structured in folders as follows:
Folder
Image no.
Description contents
START_PAGE
P00001
Setting / display of...
- node ID
- CAN baud rate
- status
- GuardErrorNode
- PLC cycle time
__MAIN_MENUES P00010
Menu
screen:
- Display setup
____MAIN_MENUE_1
______DISPLAY_SETUP
________1_DISPLAY_SETUP1 P65000
Menu
screen:
- Software version
- brightness / contrast
- display / set real-time clock
__________1_SOFTWARE_VERSION
P65010
Display of the software version.
__________2_BRIGHTNESS
P65020
Adjustment of brightness / contrast
__________3_SET_RTC
P65030
Display / set real-time clock
In the templates we have organised the image numbers in steps of 10. This way you can switch into
different language versions of the visualisations by means of an image number offset.