208
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
More functions in the ecomatmobile controller
Counter functions for frequency and period measurement
10.1.6
Function PHASE
Contained in the library:
ifm_CRnnnn_Vxxyyzz.LIB
Available for the following devices:
•
CabinetController: CR0301, CR0302, CR0303
•
ClassicController: CR0020, CR0032, CR0505
•
ExtendedController: CR0200, CR0232
•
PCB controller: CS0015
•
SafetyController: CR7020, CR7021, CR7032, CR7200, CR7201, CR7232, CR7505, CR7506
•
SmartController:
CR2500
•
PDM360 smart: CR1071
Function symbol:
PHASE
INIT
C
CHANNEL
P
ET
Description
PHASE reads a pair of channels with fast inputs and compares the phase position of the signals.
Maximum input frequency
→
data sheet.
This function compares a pair of channels with fast inputs so that the phase position of two signals
towards each other can be evaluated. An evaluation of the cycle period is possible even in the range
of seconds.
NOTE