190
ifm
System Manual
ecomat
mobile
SmartController (CR2500) V05
PWM in the ecomatmobile controller
Hydraulic control in PWM
9.3.7
Function JOYSTICK_1
Contained in the library:
ifm_HYDRAULIC_16bitOS05_Vxxyyzz.Lib
Available for the following devices:
•
ClassicController: CR0020, CR0505
•
ExtendedController:
CR0200
•
SafetyController: CR7020, CR7021, CR7200, CR7201, CR7505, CR7506
•
SmartController:
CR2500
Function symbol:
JOYSTICK_1
X
OUT1
XH_POS
OUT2
ERR1
ERR2
XL_POS
OUT3
XH_NEG
WRONG_MODE
XL_NEG
R_RAMP
F_RAMP
TIMEBASE
MODE
DEAD_BAND
CHANGE_POINT_X
CHANGE_POINT_Y
Description
JOYSTICK_1 scales signals from a joystick to configurable characteristic curves, standardised to
0...1000.
For this function the characteristic curve values can be configured (
→
figures):
Mode 0:
Linear characteristic curve
100 % = 1000 increments