10: U
SER
C
OMMUNICATION
I
NSTRUCTIONS
10-30
FC5A M
ICRO
S
MART
U
SER
’
S
M
ANUAL
FC9Y-B1268
4.
Since the Receive instruction dialog box reappears, repeat the above procedure. In the Data Type Selection dialog box, click
Skip
and click
OK
. Next, in the Skip dialog box, type
02
in the Digits box and click
OK
.
5.
Again in the Data Type Selection dialog box, click
Constant (Character)
and click
OK
. Next, in the Constant (Character) dialog
box, type
, (2Ch)
in the Character box to program a comma as a constant to verify. When finished, click
OK
.
6.
Again in the Data Type Selection dialog box, click
Variable (DR)
and click
OK
. Next, in the Variable (Data Register) dialog box,
type
D10
in the DR No. box and click
ASCII to BIN
to select ASCII to binary conversion. Enter
4
in the Digits box (4 digits) and
2
in the REP box (2 repeat cycles). Click
Variable
, select
HEX
, and type
0D
to designate a delimiter. When finished, click
OK
.
Delimiter
7.
Again in the Data Type Selection dialog box, click
BCC
and click
OK
. Next, in the BCC dialog box, enter
1
in the Calculation
Start Position box, select
ADD
for the Calculation Type, click
BIN to ASCII
for the Conversion Type, and click
2
for the Digits.
When finished, click
OK
.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]