Preface-2
FC5A MicroSmart User’s Manual FC9Y-B1268
Revision Record
The table below summarizes the changes to this manual since the first printing of FC9Y-B927-0 in April, 2006.
Upgraded and new functions listed below have been implemented in the FC5A MicroSmart CPU modules. The availability
of these functions depends on the model and the system program version of the FC5A MicroSmart CPU modules.
To confirm the system program version of the MicroSmart CPU module, use WindLDR on a computer connected with the
CPU module. The system program version is indicated on the PLC Status dialog box. See page 13-1.
To confirm the WindLDR version, select the WindLDR application button at the upper-left corner of the WindLDR screen,
followed by
WindLDR Options
>
Resources
. The WindLDR version is found under
About WindLDR
.
Upgraded and New Functions List
CPU Module
All-In-One Type
Slim Type
WindLDR
Page
FC5A-C10R2
FC5A-C10R2C
FC5A-C10R2D
FC5A-C16R2
FC5A-C16R2C
FC5A-C16R2D
FC5A-C24R2
FC5A-C24R2C
FC5A-C24R2D
FC5A-D16RK1
FC5A-D16RS1
FC5A-D32K3
FC5A-D32S3
FC5A-D12K1E
FC5A-D12S1E
(Note 1)
HMI Module Upgrade
(Note 2)
110 or higher
110 or higher
101 or higher
—
5-60
FC5A-SIF2 Expansion RS232C Communi-
cation Module Compatibility
(Note 3)
—
110 or higher
5.1 or
higher
2-86,
Advanced
Vol. 25-1
Modbus Master Upgrade
(Note 4)
—
12-6
Modbus Slave Upgrade
(Note 4)
110 or higher
110 or higher
12-14
32-bit Data Storage Setting
5.2 or
higher
5-46
Forced I/O
200 or higher
200 or higher
200 or higher
5-72
RUN LED Flashing Mode
5-49
Memory Cartridge Upload Function
(Note 5)
2-93
Off-Delay Timer Instructions
(TMLO, TIMO, TMHO, and TMSO)
7-11
Double-Word Counter Instructions
(CNTD, CDPD, and CUDD)
7-15
MOV and IMOV Instructions Upgrade
(New data type F)
Advanced
Vol. 3-1
N Data Set and N Data Repeat Set
Instructions (NSET and NRS)
Advanced
Vol. 3-13,
Advanced
Vol. 3-14
Timer/Counter Current Value Store
Instruction (TCCST)
Advanced
Vol. 3-16
CMP Instructions Upgrade
Advanced
Vol. 4-4
Load Comparison Instructions
(LC=, LC<>, LC<, LC>, LC<=, and LC>=)
Advanced
Vol. 4-8
BTOA and ATOB Instructions Upgrade
(New data type D)
Advanced
Vol. 8-9
Advanced
Vol. 8-12
Data Divide, Combine, and Swap
Instructions (DTDV, DTCB, and SWAP)
Advanced
Vol. 8-21,
Advanced
Vol. 8-22,
Advanced
Vol. 8-23
User Communication Instructions
Upgrade (TXD and RXD)
10-6, 10-15
File Data Processing Instructions
(FIFOF, FIEX, and FOEX)
Advanced
Vol. 19-1,
Advanced
Vol. 19-3
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]