Figure 3. The DC Output Bus Bars
If using the LDM outputs, an "Output" (la or − depending on polarity)
and "Return" (labelled RTN) connection are provided for each channel (see
Figure 4 and Figure 5).
Figure 4. The LDM Output
Figure 5. The LDMP Output
The LDM provides four remotely controlled and monitored outputs, with front
panel overcurrent protection provided by hydraulic-magnetic circuit
breakers (see Section 2.11 for the installation instructions for the breakers).
The LDM maximum current rating is 80 amps. Each output can accept 30
amps maximum, 25 amps continuous.
Table 8. LDM Output Capacity
System Voltage
LDM Output Capacity
24, or 48 V
Up to 4 x 30 A peak output (25 A cont.)
CAUTION
Risk of personal injury or damage to equipment and
property. Always observe the following:
•
Ensure that the combined current draw on all four LDM
outputs does not exceed the output capacity of the Power
Modules, or 80 amps, whichever is less.