![ICP DAS USA M-7024 User Manual Download Page 82](http://html1.mh-extra.com/html/icp-das-usa/m-7024/m-7024_user-manual_614159082.webp)
I-7021/22/24, M-7022/24/28 User Manual, Rev: B2.3
82
2.14 $AA5
Description:
Reads the reset status of a module.
Syntax:
$AA5[CHKSUM](CR)
$
Delimiter character
AA
Address of the module to be read (00 to FF)
5
Command to read the module reset status
Response:
Valid Command:
!AAS[CHKSUM](CR)
Invalid Command:
?AA[CHKSUM](CR)
!
Delimiter character for a valid command
?
Delimiter character for an invalid command
AA
Address of the responding module (00 to FF)
S Reset status of the module
1: This is the first time the command has been
sent since the module was powered on.
0: This is not the first time the command has
been sent since the module was powered on,
which denotes that there has been no module
reset since the last $AA5 command was sent.
There will be no response if the command syntax is
incorrect, there is a communication error, or there is no
module with the specified address.
I-7021, I-7021P, I-7022, I-7024, I-7024R
M-7022, M-7024, M-7024L, M-7024R, M-7024U, M-7028