...[HIL-1630], 449, SLOT 1 CHASSIS, INFO, chassis1, Auto-configuring
system airflow direction to Non-portside Exhaust
[HIL-1630], 449, SLOT 1 CHASSIS, INFO, chassis1, Auto-configuring
system airflow direction to Non-portside Intake
If airflow direction for power supply and fan assemblies does not match, WWN
cards will not automatically reconfigure and the fan or power supply assembly
with mismatched airflow will fault. In this case, you must replace fan or power
supply assemblies to achieve matching airflow direction for all, and then reboot
the system.
The following procedure is provided if you need to manually synchronize airflow
direction on WWN cards with airflow direction of installed fan and power supply
assemblies.
Note:
Changing chassis airflow is only supported to synchronize established
airflow direction of installed fan and power supply assemblies with airflow
direction configured on WWN cards. Changing airflow direction from NPI to NPE
or NPE to NPI is not supported in a customer environment.
Procedure
1.
Enter
chassisShow
to display airflow direction programmed in WWN cards and
airflow direction of installed fan and power supply FRUs. Airflow direction of
fans and power supplies displays as "Fan Direction" under each fan or power
supply unit. System airflow direction displays as "System Airflow" under the
WWN card unit. The following example shows mismatch of system airflow and
airflow direction in installed fan and power supply as the WWN units should
indicate "Non-portside Intake."
POWER SUPPLY
Unit: 1
Power Source:
AC
Fan Direction:
Non-portside Intake
...
FAN
Unit: 2
Fan Direction:
Non-portside Intake
...
WWN
Unit: 1
System AirFlow:
Non-portside Exhaust
...
WWN
Unit: 2
System AirFlow:
Non-portside Exhaust
2.
To reconfigure airflow direction on installed WWN cards, enter
wwnrecover
.
sw0:admin> wwnrecover
WWN 1 and/or WWN 2 system airflow direction mismatches with the
installed fan FRU’s airflow direction.
WWN Non-Critical Seeprom Problem Details
WWN 1 system airflow direction mismatches with installed Fan FRU’s
airflow direction!!!!
WWN 2 system airflow direction mismatches with installed Fan FRU’s
airflow direction!!!!
Recovery Options
0. Exit
1. Copy Airflow direction from Fan FRU to both WWN cards
3.
Enter 1 when prompted for a recover option to copy airflow direction from the
fan to both WWN cards.
158
SAN512B-6 Installation, Service, and User Guide
Summary of Contents for SAN512B-6
Page 2: ......
Page 8: ...vi SAN512B 6 Installation Service and User Guide...
Page 10: ...viii SAN512B 6 Installation Service and User Guide...
Page 12: ...x SAN512B 6 Installation Service and User Guide...
Page 40: ...16 SAN512B 6 Installation Service and User Guide...
Page 60: ...36 SAN512B 6 Installation Service and User Guide...
Page 128: ...104 SAN512B 6 Installation Service and User Guide...
Page 140: ...116 SAN512B 6 Installation Service and User Guide...
Page 170: ...146 SAN512B 6 Installation Service and User Guide...
Page 184: ...160 SAN512B 6 Installation Service and User Guide...
Page 196: ...172 SAN512B 6 Installation Service and User Guide...
Page 208: ...184 SAN512B 6 Installation Service and User Guide...
Page 258: ...234 SAN512B 6 Installation Service and User Guide...
Page 274: ...250 SAN512B 6 Installation Service and User Guide...
Page 285: ......
Page 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...