The WWN units should indicate "Non-portside Intake." If there is a mismatch
of airflow direction, RASlog messages will indicate a mismatch between system
airflow direction and airflow direction of fan in power supply or fan assembly
refer to “Configuring airflow direction on WWN cards” on page 157 for
instructions on configuring correct airflow direction on WWN cards.
3.
Enter the
slotShow -m
command and verify that all the installed cards are
detected and that their status is operational (enabled).
switch:admin> slotShow -m
Slot
Blade Type
ID
Model Name
Status
--------------------------------------------------
1
CP BLADE
175
CPX6
ENABLED
2
CP BLADE
175
CPX6
ENABLED
3
SW BLADE
178
FC32-48
ENABLED
4
SW BLADE
178
FC32-48
ENABLED
5
AP BLADE
186
SX6
ENABLED
6
SW BLADE
178
FC32-48
ENABLED
7
CORE BLADE
176
CR32-8
ENABLED
8
CORE BLADE
176
CR32-8
ENABLED
9
SW BLADE
178
FC32-48
ENABLED
10
AP BLADE
186
SX6
ENABLED
11
SW BLADE
178
FC32-48
ENABLED
12
SW BLADE
178
FC32-48
ENABLED
switch:admin>
4.
Verify that the device is functioning correctly by entering
switchShow
or
switchStatusShow
.
This
switchShow
command displays the device and port status information.
switch15:admin> switchshow
switchshow>
switchshow
switchName:
sw15
switchType:
166.0
switchState:
Online
switchMode:
Native
switchRole:
Subordinate
switchDomain:
1
switchId:
fffc01
switchWwn:
10:00:00:23:f8:f2:15:82
zoning:
ON (MPR4k)
switchBeacon:
OFF
FC Router:
OFF
FC Router BB Fabric ID: 128
Address Mode:
0
Fabric Name:
BB1
HIF Mode:
OFF
Index Slot Port Address Media Speed
State
Proto
=======================================================
0
3
0
010000
id
32G
Online
FC
F-Port 20:00:00:27:f8:f3:15:80
1
3
1
010100
id
32G
Online
FC
F-Port 20:01:00:27:f8:f3:15:80
2
3
2
010200
id
32G
Online
FC
F-Port 20:02:00:27:f8:f3:15:80
3
3
3
010300
id
32G
Online
FC
F-Port 20:03:00:27:f8:f3:15:80
4
3
4
010400
id
32G
Online
FC
F-Port 20:04:00:27:f8:f3:15:80
5
3
5
010500
id
32G
Online
FC
F-Port 20:05:00:27:f8:f3:15:80
6
3
6
010600
id
32G
Online
FC
F-Port 20:06:00:27:f8:f3:15:80
(output truncated)
5.
Verify that all the IP address information is correct by entering
ipAddrShow
and
checking the results against the IP information recorded in the
config-miscinfo.txt file.
switch:admin> ipaddrshow
SWITCH
Ethernet IP Address: xxx.xxx.xxx.12
Ethernet Subnetmask: 255.55.0.0
Fibre Channel IP Address: 1.2.3.4
Fibre Channel Subnetmask: 255.255.255.0
Chapter 16. Replacing the Chassis
201
Summary of Contents for SAN512B-6
Page 2: ......
Page 8: ...vi SAN512B 6 Installation Service and User Guide...
Page 10: ...viii SAN512B 6 Installation Service and User Guide...
Page 12: ...x SAN512B 6 Installation Service and User Guide...
Page 40: ...16 SAN512B 6 Installation Service and User Guide...
Page 60: ...36 SAN512B 6 Installation Service and User Guide...
Page 128: ...104 SAN512B 6 Installation Service and User Guide...
Page 140: ...116 SAN512B 6 Installation Service and User Guide...
Page 170: ...146 SAN512B 6 Installation Service and User Guide...
Page 184: ...160 SAN512B 6 Installation Service and User Guide...
Page 196: ...172 SAN512B 6 Installation Service and User Guide...
Page 208: ...184 SAN512B 6 Installation Service and User Guide...
Page 258: ...234 SAN512B 6 Installation Service and User Guide...
Page 274: ...250 SAN512B 6 Installation Service and User Guide...
Page 285: ......
Page 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...