Table 10. Port blade LED descriptions (continued)
LED purpose
Color
Status
Recommended action
Status
No light (LED is off)
Blade is either healthy or
does not have power.
Verify that the power LED
is on.
Steady amber
Blade is faulty.
Ensure that the blade is
firmly seated and check the
status by entering the
slotShow
command. If LED
remains amber, consult the
device supplier.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Blade is not seated correctly
or is faulty.
Pull the blade out and
reseat it. If LED continues
to flash, replace the blade.
Fast-flashing amber (on 1/2
second, then off 1/2
second)
Environmental range
exceeded.
Check for out-of-bounds
environmental condition
and correct it.
FC port Status
No light (LED is off)
Port has no incoming
power, or there is no light
or signal carrier detected.
Verify that the power LED
is on, check the transceiver
and cable.
Polling is in progress.
Allow 60 seconds for
polling to complete.
Connected device is
configured in an offline
state.
Verify the status of the
connected device.
Steady green
Port is online (connected to
an external device) but has
no traffic.
No action required.
Slow-flashing green (on 1
second, then off 1 second)
Port is online but
segmented, indicating a
loopback plug or cable or
an incompatible switch.
Verify that the correct
device is attached to the
chassis.
Fast-flashing green (on 1/4
second, then off 1/4
second)
Port is in internal loopback
(diagnostic).
No action required.
Flickering green
Port is online, with traffic
flowing through port.
No action required.
Steady amber
Port is receiving light or
signal carrier, but it is not
online yet.
Reset the port from the
workstation using the
portEnable
or
portCfgPersistentEnable
command.
Slow-flashing amber (on 2
seconds, then off 2 seconds)
Port is disabled due to
diagnostic tests or
portDisable
or
portCfgPersistentEnable
command.
Reset the port from the
workstation using the
portEnable
or
portCfgPersistentEnable
command.
Fast-flashing amber (on 1/2
second, then off 1/2
second)
Transceiver or port is faulty. Change the transceiver or
reset the switch from the
workstation.
Alternating green/amber
Port is beaconing.
No action.
Chapter 6. Monitoring the switch
71
Summary of Contents for SAN512B-6
Page 2: ......
Page 8: ...vi SAN512B 6 Installation Service and User Guide...
Page 10: ...viii SAN512B 6 Installation Service and User Guide...
Page 12: ...x SAN512B 6 Installation Service and User Guide...
Page 40: ...16 SAN512B 6 Installation Service and User Guide...
Page 60: ...36 SAN512B 6 Installation Service and User Guide...
Page 128: ...104 SAN512B 6 Installation Service and User Guide...
Page 140: ...116 SAN512B 6 Installation Service and User Guide...
Page 170: ...146 SAN512B 6 Installation Service and User Guide...
Page 184: ...160 SAN512B 6 Installation Service and User Guide...
Page 196: ...172 SAN512B 6 Installation Service and User Guide...
Page 208: ...184 SAN512B 6 Installation Service and User Guide...
Page 258: ...234 SAN512B 6 Installation Service and User Guide...
Page 274: ...250 SAN512B 6 Installation Service and User Guide...
Page 285: ......
Page 286: ...IBM Part Number 01JC152 Printed in USA SC27 8966 02 1P P N 01JC152...